HomelinessTools and equipment

Toilet bowl with vertical drain: installation instructions

The toilet with vertical drain is optimally suited for premises in which the sewer pipe is under the floor, and the neck is brought to the toilet itself and placed under it. For other situations, for example, when the pipeline is located in the wall or above the floor surface, plumbing with horizontal and oblique discharge is used.

Description

This construction can often be found in the bathrooms in new buildings and apartments with a modern design. The toilet with a vertical drain to the floor should be located exactly above the neck of the pipeline, so the installation process is characterized by some difficulties and the need to comply with all marks. Plumbing devices also require special installation accuracy. Before choosing a particular option, you need to measure the distance from the sewer neck to the wall.

Materials

There are several basic materials used to create sanitary ware, among which are the following:

  • Faience is characterized by low cost and resistance to household chemicals. Despite its prevalence, it is not devoid of shortcomings, the main among which is a surface with a large number of pores, because of which it quickly accumulates pollution. Today, methods are used to eliminate this problem, for example, glazing.
  • Artificial stone (polymer concrete) is a material created from acrylic and quartz sand. Has a beautiful and non-standard texture. A characteristic feature is the low resistance to chemicals, in particular, to abrasives, alkalis and concentrated acids.
  • Porcelain belongs to the budget category. It has a smooth surface and is easily cleaned with standard household products due to the absence of pores.
  • Stainless steel is used to create anti-vandal toilet bowls, differing in specific appearance, unusual for most buyers and high cost. As a rule, they are installed in cafes, restaurants and other common areas.

Shape and drain

A toilet bowl with a vertical drain can have a different shape, which depends on the location of the water mirror. There are two main options - front and rear. In the first case, more frequent cleaning with a brush is required, but there are no splashes. In the rear location, the surface is less often contaminated, but there is a problem with the presence of splashes. To eliminate it, the "Antivsplesk" system, which is a rounded ledge located above the outlet, is often used today. The size of the vertical drain of the toilet bowl is selected depending on the size of the bell.

The most common are circular and back drains. The latter perfectly cleans the most polluted part of the bowl, but it may not affect the rest of the surface. The circular version provides complete cleaning.

How to choose the best option

Among all models, the most common are the toilet bowls with a straight vertical drain, Made of porcelain. They differ in an easily cleaned surface and are not much more expensive than faience. To ensure maximum cleanliness and reduce the number of sprays, it is worth to choose the option with the rear location of the mirror and equipment in the form of the system "Anti-splash".

Circular drain will simplify cleaning, and reliable fittings, manufactured by a well-known manufacturer, will provide long-term comfortable operation. Also it is desirable to equip in the form of a double drain.

When you need a toilet with a vertical sink?

In many cases, it is not necessary to choose the release options, since the use of one or the other is dictated by the installation of sewerage. Such a model, as a rule, is established in the case that the socket of the sewage system is on a level with the floor. This type of sewage pipes is common in houses built in the 40-60s of the last century. The bell is connected to a riser located next to the wall outlet with an oblique tee. It is worth noting that the gangway was installed earlier under the ceiling in the underlying apartment and often led to scandals among neighbors.

Today, mostly there is a floor installation of sewerage, to which the sanitary ware with a straight and horizontal outlet is suitable. This principle of laying simplifies the installation and allows you to quickly move the toilet to the desired place without any difficulties. Despite this, the toilet with a vertical sink, the photo of which is presented above, is popular with people living in private estates. This is due to several reasons, the main one being easy access to the sewerage, provided by the presence of an underground space or a cellar. Thus, there is no difficulty in maintaining and repairing the system. Also, thanks to the release of this type of sewage pipe remains hidden, which significantly improves the appearance of the room.

Dismantling

To begin with, fasteners. If the toilet is additionally fixed with a sealant, it is separated from the floor with a light blow, facing upwards. You can also use a chisel located under the base.

The structure is turned and pulled up. It is worthwhile to be careful, as crumbling cement and other small debris can get into the sewer pipe. This is highly undesirable because of the high probability of gaps.

Installation

Despite the fact that the installation of plumbing devices does not require specific skills, there may be some difficulties that can be easily solved by understanding the intricacies of the process.

The tightness of the joint is achieved by using an annular cuff made of rubber. In the presence of contaminants on the socket, the surface must be thoroughly cleaned, then fix the cuff with a sealant. Then the fixing points are marked and holes are drilled, after which the toilet bowl is installed with a vertical drain and fixation with screws. In addition to airtightness, the rubber cuff will ensure the absence of unpleasant odors. If the plumbing is mounted on an uneven floor surface, the formed slots must be filled with a sealant or cement mortar.

Installation of a toilet bowl with release of other type

If the room has plumbing with a vertical outlet, if necessary, it can be replaced with a product with a horizontal and oblique type, but it should be borne in mind that its location will be changed.

To perform this task, a sewer corrugated pipe equipped with sealing cuffs is required.

Sanitary equipment is fixed with standard fixture, and the distance between the sewer pipe and the outlet should be minimal. Corrug, covered with a layer of sealant, is inserted into the socket. The other part of the corrugated pipe is installed on the outlet, also treated with sealant.

The corrugation should have the same slope to the bell on the whole part, and there must be no creases and irregularities.

Toilet bowl displacement

If you need to move the toilet bowl with a vertical drain without using a corrugation, the following action algorithm is used. The plumbing is dismantled from the previous location, after which the bell is cleaned of debris. In it, you need to insert a sewer and cuff, which are directed towards the desired location of the toilet.

With the help of the pipe, the funnel extends to the required length, after an additional corner it turns upwards. Sealant is used to assemble all connections. Plumbing is installed on a concrete pedestal, after laying the selected coating on the surface.

Mounting Features

Sewage corrugation provides connection even in confined spaces. It is made of plastic and has a stretchy ribbed surface. The first stage of installation of any plumbing is the marking of the location and used fasteners. When putting on ruffles, you need to remember that it should slide on it at least 4-5 cm.

It is especially important to check the tightness of the connections. To do this, it is necessary to pour a large amount of water into the toilet and look at the joints, in the absence of a leakage it is possible to fix a toilet bowl with a vertical drain. The installation is completed, only the connections are sealed and the drain tank connected.

Similar articles

 

 

 

 

Trending Now

 

 

 

 

Newest

Copyright © 2018 en.atomiyme.com. Theme powered by WordPress.